Air filters for wildfire smoke, ranked by what they catch

A true HEPA filter in a portable air cleaner catches the most wildfire smoke. It's rated to trap at least 99.97% of particles at 0.3 microns, the size that gets through filters most easily. For a home's central system, the EPA and the California Air Resources Board say to use a MERV 13 filter or higher.

On this page
  1. The short version
  2. How are these filters ranked?
  3. The ranking
  4. Why isn't a high rating enough?
  5. How well does a box fan filter work?
  6. Will an air filter get rid of the smoke smell?
  7. What if the smoke gets into the house anyway?
  8. What should you do before smoke season?
  9. Questions people ask
  10. Sources
A taupe two-story stucco house with a two-car garage and an orange tree, on a hillside of dry grass and shrubs
For a house with a central system, the EPA and the California Air Resources Board say to use a MERV 13 filter or higher.

The short version

  • A true HEPA filter catches the most smoke in one pass, at least 99.97% of particles at 0.3 microns.
  • For a central system, the EPA and CARB set MERV 13 as the minimum, which has to catch at least 50% of the smallest particles tested.
  • A filter only works while air moves through it, so run a portable unit nonstop on high and set a central system's fan to "On."
  • Set up your filters before smoke season, because the EPA's smoke guide warns that air cleaners can be hard to find during a smoke emergency.

How are these filters ranked?

They're ranked by the share of the smallest tested particles each one catches in a single pass. Smoke particles are tiny. CARB says they can be 2.5 micrometers across or smaller (a micrometer, or micron, is a millionth of a meter).

Home heating and cooling filters are tested under ASHRAE Standard 52.2. ASHRAE is the engineers' society for heating and air conditioning. Its test measures how much a filter catches in 3 size bands: 0.3 to 1 micron, 1 to 3 microns and 3 to 10 microns. The result is a MERV rating from 1 to 16. The EPA publishes the minimum each rating has to catch.

This ranking uses the smallest band, 0.3 to 1 micron. Filters rated below MERV 11 don't have to catch anything in it. HEPA filters aren't rated on the MERV scale. The Department of Energy defines them. The EPA lists them next to MERV 16 so the two can be compared.

A rating describes one pass through the filter. How clean a room gets also depends on how much air goes through. That's the section after the ranking.

Rank Filter Smallest particles caught (0.3 to 1 micron)
1 True HEPA, in a portable air cleaner At least 99.97% at 0.3 microns
2 MERV 16 At least 95%
3 MERV 14 or 15 At least 75% or 85%
4 MERV 13, in a central system or a box fan build At least 50%
5 MERV 11 or 12 At least 20% or 35%
6 MERV 5 to 10 No minimum in this band
7 MERV 1 to 4 Not tested in this band
8 The filter in a window AC or ductless mini-split No rating

The ranking

1. A true HEPA filter in a portable air cleaner

Catches: at least 99.97% of particles at 0.3 microns.

The EPA calls 0.3 microns the "most penetrating particle size," which means it's the hardest size for a filter to stop. Particles that are bigger or smaller are trapped at an even higher rate. The EPA says portable air cleaners often get a high CADR, the room rating explained below, from a HEPA filter.

A portable unit cleans one room, so size it to that room (see "How big an air cleaner do you need?" below). Every portable air cleaner sold in California has to be certified by CARB. Units that use only pleated or HEPA filters don't make ozone.

2. MERV 16

Catches: at least 95% in all 3 size bands.

MERV 16 is the top of the MERV scale. It goes in a central heating and cooling system, if the system's fan and filter slot can take it. The EPA says to use "as high a rating as your system fan and filter slot can accommodate." It suggests asking an HVAC technician which filter that is.

3. MERV 14 or 15

Catches: at least 75% (MERV 14) or 85% (MERV 15) of the smallest particles.

Both catch at least 90% in the 1 to 3 micron band and 95% in the 3 to 10 micron band. They're a step up from MERV 13 for a system that can handle them.

4. MERV 13

Catches: at least 50% of the smallest particles, 85% at 1 to 3 microns and 90% at 3 to 10 microns.

MERV 13 is the floor the EPA and CARB both set for smoke. The EPA says most furnaces and central systems can take a MERV 13 without equipment problems, as long as the filter is replaced often. It's also the filter the EPA used in its box fan research, which has its own section below.

5. MERV 11 or 12

Catches: at least 20% (MERV 11) or 35% (MERV 12) of the smallest particles.

These are the first ratings that have to catch anything in the 0.3 to 1 micron band. Use one only if your system can't take a MERV 13.

6. MERV 5 to 10

Catches: no minimum for the smallest particles.

A MERV 8 has to catch at least 20% of particles from 1 to 3 microns and 70% from 3 to 10 microns. MERV 5 to 7 are tested only on the largest band. The test doesn't ask any of them to catch the smallest particles.

7. MERV 1 to 4

Catches: less than 20% of particles from 3 to 10 microns.

The test doesn't measure these filters on the 2 smaller bands. For smoke, swap one out for the highest rating your system can take.

8. The filter in a window AC or ductless mini-split

Catches: no published rating.

The EPA says these units have limited filtration "intended to keep the inside of the air conditioner clean rather than remove fine particles." A ductless mini-split still has a use on a smoke day. The EPA's smoke guide says it cools a sealed-up house without bringing in outside air. It just won't clean the air much.

What doesn't make the list

  • Ozone generators. The EPA says ozone "does not remove particles" from the air. It also says breathing ozone can damage the lungs. No federal agency has approved these devices for rooms people are in.
  • Ionizers. The EPA found they catch less tobacco smoke than high-efficiency filters. Its smoke guide says the particles they charge stick to walls and carpet, where they can be stirred back up. They're also often a source of ozone. In California, an electronic air cleaner has to stay under CARB's ozone limit of 0.050 parts per million to be sold.
  • Humidifiers. The EPA's smoke guide says they aren't air cleaners and won't reduce particles much.
  • Swamp coolers and whole house fans. CARB says not to run them in smoke. The EPA's smoke guide says a swamp cooler brings large amounts of outside air into the house.

CARB's certification is about ozone and electrical safety. CARB says it doesn't test how well an air cleaner removes pollutants.

Why isn't a high rating enough?

A filter only cleans the air that goes through it. The EPA says an air cleaner filters less air at a lower speed. Running it longer filters more.

In a central system

The EPA says furnace and HVAC filters "work to filter the air only when the system is operating." On "Auto," most systems run less than a quarter of the time in heating and cooling seasons.

On a smoke day, the EPA says to do 2 things:

  1. Set the thermostat's fan to "On" instead of "Auto," so air keeps passing through the filter.
  2. Set the system to recirculate, or close the outdoor air intake. If you have a fresh air ventilation system, turn it off.

The EPA's smoke guide suggests a reminder tag by the thermostat, so you switch back once the smoke clears. Running the fan all the time uses more energy.

How big an air cleaner do you need?

Check the box for its clean air delivery rate (CADR). The rating combines how well the filter catches particles with how much air the unit moves. It's usually measured at the highest speed. The AHAM Verifide label, from the appliance makers' trade group, lists 3 CADRs: tobacco smoke, dust and pollen. Use the tobacco smoke number, because it stands for the smallest particles.

The EPA's smoke guide gives a rule of thumb. The tobacco smoke CADR should be at least two thirds of the room's floor area in square feet. A 10 by 12 foot bedroom is 120 square feet, so it needs a CADR of at least 80.

The EPA's sizing chart assumes 8-foot ceilings:

Room area (square feet) Minimum CADR
100 65
200 130
300 195
400 260
500 325
600 390

Pick a bigger unit for ceilings over 8 feet. In an open floor plan, measure the whole open space. If the space is larger than any unit covers, the EPA suggests using more than one.

CARB says to run a certified air cleaner continuously on its highest setting. Put it in the room you spend the most time in and keep curtains and furniture out of its airflow. Keep outside doors and windows closed. If you're setting up one room to ride out the smoke in, how to set up a clean room for smoke days has the steps.

An air cleaner helps, but it won't take out all the smoke. The EPA's smoke guide cites a study that found these units can cut indoor particles by as much as 45% during a smoke event. In normal conditions, another study found reductions of up to 90%.

How well does a box fan filter work?

A box fan with MERV 13 filters attached can cut the smoke in a room. Builds with more filters did better. The EPA tested 5 builds in its lab against wildfire smoke and measured their CADR:

Box fan build (MERV 13 filters) CADR for wildfire smoke
One 1-inch filter 111
One 1-inch filter with a cardboard shroud 156
One 4-inch filter with a cardboard shroud 248
Two 1-inch filters with a cardboard shroud 263
Corsi-Rosenthal box: four 1-inch filters with a shroud 401

Adding a cardboard shroud raised the CADR by 40% without making the build any bigger. For scale, the EPA's sizing chart asks for 390 in a 600 square foot room. These numbers come from a lab, so treat them as a guide rather than a match for a certified label.

There are 4 safety rules from the EPA and CARB:

  • Use a box fan made in 2012 or later. The EPA says fans built before 2012 weren't tested and "pose known fire risks."
  • Look for a UL or ETL mark. The EPA names the UL 507 safety standard.
  • Never leave it running while you're out or asleep.
  • Change the filters when they're dirty or start to smell. The EPA found the builds were "almost completely ineffective with dirty filters."

The EPA still says an air cleaner from a store with a known CADR is typically preferred. It lists noise and heat from the fan among a box fan build's drawbacks.

Will an air filter get rid of the smoke smell?

Mostly not. Smoke smell comes from gases, which HEPA and MERV filters aren't made to catch. The EPA says CADR covers particles only.

To take out gases, the EPA says to look for an air cleaner with an activated carbon filter or another filter made for gases. It works when there's a lot of carbon in it. The thicker the filter, the better. There's no widely used rating for gas filters, so you can't compare them the way you compare CADR. The EPA's smoke guide adds that the carbon in a small unit can fill up fast and need changing often.

What if the smoke gets into the house anyway?

A filter only cleans the air that moves through it. Smoke that has already settled on the walls, the carpet and the furniture stays put. So does the smell, which these filters aren't made to catch.

If soot or a smoke smell stays after the fire, take dated photos. Then ask your insurer in writing what your policy pays to clean it. Casa, whose team runs this site and quotes California home insurance, has a guide to living costs after a California disaster. It says a smoke-damaged home that still stands can qualify for additional living expense coverage, or ALE, which pays the extra cost of staying somewhere else. It quotes a February 5, 2025 Department of Insurance alert about homes that a health department or another agency finds unsafe. The alert says the insurer "should extend ALE benefits until your home is deemed safe to live."

What should you do before smoke season?

Do these while the air is clear:

  1. Find your filter size. The EPA says home filters come 1 to 5 inches thick. A new filter should fit snugly without bending, so air can't leak around it.
  2. Compare by MERV. Some boxes show FPR or MPR instead. The EPA says those are rating methods owned by the companies that use them, while MERV comes from a national standard.
  3. Ask an HVAC technician whether your system can take a MERV 13 or higher. The EPA says most systems aren't labeled with a filter recommendation.
  4. Check CARB's certified list before you buy a portable air cleaner. It's updated as devices are approved.
  5. Keep spare filters. Manufacturers usually say to change them every 60 to 90 days. If a filter looks heavily soiled when you change it, change it more often.
  6. Measure the room you'd use on a smoke day. Then size the air cleaner to it with the chart above.

Questions people ask

Is a MERV 13 filter as good as a HEPA filter? No. A MERV 13 has to catch at least 50% of particles from 0.3 to 1 micron, while a true HEPA filter catches at least 99.97% at 0.3 microns. MERV 13 is the minimum the EPA and CARB set for smoke.

Will a MERV 13 filter damage my furnace? The EPA says most furnaces and central systems can take one without equipment problems if you change it often. An HVAC technician can confirm what yours can handle.

Should I run my air purifier all the time during smoke? Yes. CARB says to run a certified air cleaner continuously on its highest setting while there's smoke.

Is a box fan air filter safe to run overnight? No. The EPA says box fan builds shouldn't run unattended or while you sleep. Use a fan made in 2012 or later with a UL or ETL mark.

Are ionizers good for wildfire smoke? The EPA found ionizers catch less smoke than high-efficiency filters. They're often a source of ozone. California allows an electronic air cleaner only if it stays under CARB's ozone limit.

Sources